This equipment is mainly used for testing new energy harness. The test items include: continuity test, air tightness test, ac withstand test, dc withstand test, insulation resistance test, precision resistance test. It is a high-performance wiring harness test system for new energy automobiles, ship, bullet trains and home appliances etc.
Performance Characteristics
The equipment is equipped with overvoltage protection, overcurrent protection, leakage protection, and safety grating protection, which can greatly protect the safety of operators.
Support the arbitrary point to point test.
Humanized software operation interface to help administrators edit test procedures quickly.
With administrator and operator double password, effectively ensure the control and security of the test program.
It has the function of synchronous recording of test data to help customers timely understand product quality.
Printer function, arbitrary edit print content.
Barcode scanning automatically loads test file, scan code test.
Voice broadcast test results.
Technical Specifications
Output voltage | ||||
AC | output | 0.05 - 5kV | ||
Measurement accuracy | 1% ± 5V | |||
Display accuracy | 2V | |||
frequency | 50Hz / 60Hz | |||
power | maxium 150VA | |||
DC | output | 0.05 - 6kV | ||
Measurement accuracy | 1% ± 5V | |||
Display accuracy | 2V | |||
power | maxium 60VA | |||
IR | output | 0.05 - 1kV | ||
Measurement accuracy | 1% ± 5V | |||
Display accuracy | 2V | |||
Output current | ||||
AC | output | 30mA | ||
Measurement accuracy | 1% ± 5counts ( 5%±20 counts for real current ) | |||
Display accuracy | 1µA | |||
frequency | 50Hz/60Hz | |||
DC | output | 10mA,display accuracy:0.1µA | ||
Measurement accuracy | 1% ± 5counts ( 5%±20 counts for real current ) | |||
Display accuracy | 0.1µA | |||
Insulation resistance | ||||
IR | voltage | DC range: 0.05 - 1kV, voltage accuracy: 1.5% ± 5V | ||
Measurement range | 1MΩ-50GΩ | 1MΩ-10GΩ | ||
Measurement display accuracy | 0.1MΩ | |||
Measurement accuracy | ≥500V: 1MΩ-1GΩ :±5%±10 counts, | |||
ARC Test | ||||
Setting method | Programmable | |||
the range of cutting off current | AC:1mA-15mA, DC: 1mA-10mA | |||
detection time | 10µs approx | |||
Precision Resistance Test | ||||
Continuity | Setting Range 0.1-500K | |||
Resistance | 0.1-100KΩ; ±3%±0.1 | |||
100K-1MΩ; ±5% | ||||
0.01-75Ω; ±3%±0.01 |