UC9908S(AC/DC/IR/SCAN/CK Eight channel)
UC9908S series programmable safety tester has AC withstand voltage test, DC withstand voltage test, insulation resistance test, scan test and contact checking function.
Product Detail

Brief introduction
UC9908S AC and DC withstand voltage insulation tester is a high performance tester with a new technology. The unique current protection function and high precision output voltage can make the instrument safe. At the same time, more accurate and faster testing can be provided. Maximum 88-channel withstand voltage output(optional), can meet the full range of customer requirements UC9900 series withstand voltage tester is mainly used to detect the safety performance of instruments, equipment and components .


Performance characteristics
■ UC9908S is host device,UC1908S is slave device
■ Test function AC/DC/IR
■ Display: large LCD display
■ AC voltage output:50V - 5kV, AC current: 30mA
DC voltage output:50V - 6KV, DC current: 10mA
■ Wide insulation resistance measurement range:1MΩ - 50GΩ
■ Ground connection test GC(optional function)
■ Current upper and lower limits setting of programmable leakage current
■ IR, DC test discharge function rapidly
■ Standard RS-232communication interface, optional GPIB


Instrument accessories
UC90001R high voltage test cable(each channel with a cable)
UC90001B a ground cable
A power cord


Type

UC9908S host

UC1908S slave

Function

ACV/DCV/IR/SCAN

ACV/DCV/IR/SCAN

Output channel

8channel

8channel

output voltage

AC

output

0.05 - 5kV

Measurement accuracy

1% ± 5V

Display accuracy

2V

frequency

50Hz / 60Hz

power

maxium 150VA

DC

output

0.05 - 6kV

Measurement accuracy

1% ± 5V

Display accuracy

2V

power

maxium 60VA

IR

output

0.05 - 1kV

Measurement accuracy

1% ± 5V

Display accuracy

2V

Output current

AC

output

30mA

Measurement accuracy

1% ± 5counts ( 5%±20 counts for real current )

Display accuracy

1µA

frequency

50Hz/60Hz

DC

output

10mA,display accuracy:0.1µA

Measurement accuracy

1% ± 5counts ( 5%±20 counts for real current )

Display accuracy

0.1µA

Insulation resistance

IR

voltage

DC range: 0.05 - 1kV, voltage accuracy: 1.5% ± 5V

Measurement range

1MΩ-50GΩ

1MΩ-10GΩ

Measurement display accuracy

0.1MΩ

Measurement accuracy

≥500V: 1MΩ-1GΩ :±5%±10 counts,
1GΩ-10GΩ :±10%±10 counts,
10GΩ-50GΩ :±15%±10 counts;
≤500V:0.1MΩ-1GΩ:±10%±10 counts

ARC Test

Setting method

programmable

the range of cutting off current

AC:1mA-15mA, DC:1mA-10mA

detection time

10µs approx

Protection function

Fast cut off time

0.4ms after NG happer

Fast discharge time

0.2sec

Ground failure starting current

0.5mA±0.25mA AC, Close

Dimension

Carton Package

470mm*280mm*550mm

Weight(KG)

17KG